Hot Water Heat Pump

Technical InformationValue
Noise48 dB(A)
Ambient Temperature Limits (for heat pump operation – element will operate beyond these limits)-1°C – 45°C
Ingress ProtectionIP24IP24
Storage Cylinder – Hot Outlet and Cold inlet ConnectionsISO 7.1 ¾” RP
Storage Cylinder – PTR Valve ConnectionISO 7.1 ½” RP
PTR Setting1000 kPa / 10 kW
ECV FittedFit PLV if mains pressure exceeds680 kPa
Recommended PLV pressure rating500 kPa
ECV Not FittedFit PLV if mains pressure exceeds800 kPa
Recommended PLV pressure rating500 kPa
Rated Input Electric Element (Factory Wired)2.4 kW
Rated Input Refrigeration Module (Factory Wired)1.0 kW
Total Rated Input (To be wired by installer)3.4 kW
Maximum Energy Output4.29 kW
Power Supply240 V AC, 50Hz
Current15 A
Refrigerant Type / MassR290 / 270g
COP (32.6°C Ambient 21.1°C cold water inlet)7.22
Heat Pump heating capacity (32.6°C Ambient 21.1°C cold water inlet)5.2 kW