Technical Information | Value |
Noise | 48 dB(A) |
Ambient Temperature Limits (for heat pump operation – element will operate beyond these limits) | -1°C – 45°C |
Ingress Protection | IP24IP24 |
Storage Cylinder – Hot Outlet and Cold inlet Connections | ISO 7.1 ¾” RP |
Storage Cylinder – PTR Valve Connection | ISO 7.1 ½” RP |
PTR Setting | 1000 kPa / 10 kW |
ECV Fitted | Fit PLV if mains pressure exceeds | 680 kPa |
Recommended PLV pressure rating | 500 kPa |
ECV Not Fitted | Fit PLV if mains pressure exceeds | 800 kPa |
Recommended PLV pressure rating | 500 kPa |
Rated Input Electric Element (Factory Wired) | 2.4 kW |
Rated Input Refrigeration Module (Factory Wired) | 1.0 kW |
Total Rated Input (To be wired by installer) | 3.4 kW |
Maximum Energy Output | 4.29 kW |
Power Supply | 240 V AC, 50Hz |
Current | 15 A |
Refrigerant Type / Mass | R290 / 270g |
COP (32.6°C Ambient 21.1°C cold water inlet) | 7.22 |
Heat Pump heating capacity (32.6°C Ambient 21.1°C cold water inlet) | 5.2 kW |